Full AT Command Set Listing For SupraFAXModem v.32bis NOTE: This file includes commands not available on all models & revisions. Not all commands are available or functional in all modes & states. AT_LIST.TXT Rev 1.5 (PHM 5/2/93) from Supra BBS (503)967-2444 @ Dialing Command - wait for "quiet answer" , Dialing Command - pause (time set in S8) before finishing dialing string ! Dialing Command - hook flash (go on-hook for 700ms) ^ Dialing Command - turn on call originating tone ; Dialing Command - return to command state after dialing (last command) +++ Default Escape Code A Answer Phone Line A/ Re-execute Last Command (this command NOT preceded by AT) Bn BELL/CCITT mode switch at 300 & 1200 bps B0=CCITT B1=BELL (default in North America) D Dial Command Dials any mixed string of dialing commands and the following list of symbols: 0123456789ABCD#* En Command Echo E0=not echo E1=do echo (default) Hn Hook Control H0=On-Hook (Hang Up) H1=Off-Hook (pick up phone line) In Identification Codes I0=SupraFAXModem product ID code I1=ROM checksum I2=Test Checksum (OK if correct, ERROR if not) I3=ROM revision code I4=Encrypted report of supported protocols I5=Supra Copyright info. I10=Supported Features (encoded) L Dialing command - dials last string dialed Ln Speaker Volume L0&L1 Low L2 Medium (default) L3 High Mn Speaker Control M0 OFF M1 On until carrier is received (default) M2 Always On M3 On when answering/On only after dialing & until carrier detect Nn Connection Rate when Originating Call N0=Connect ONLY at rate set in S37 register N1=Connect Normally (default) On Return from COMMAND MODE to ONLINE state O0=Return to ONLINE state O1=Request a retrain & Return to ONLINE state P Set Pulse Dialing Qn Result Code Mode Q0=Enabled (Default) Q1=Disabled Q2=Enabled when Originating, Disabled when answering R Dialing command - reverse to answer mode after dialing (this MUST be the last command in the dialing string) Sr? Reports value in S register r SCr? Reports value is SC register r Sr=n Write value n into S register r SCr=n Write value n into SC register r Sx Dialing command - dials number stored in memory area x T Set Tone Dialing Vn Result Code mode select V0=Numeric V1=Verbose (default) W Dialing command - wait for dial tone before finishing string Wn Error Correction Result Code Selection W0=CONNECT XXXX (DTE rate) (default) W1=Report Error Correction Mode W2=CONNECT XXXX (DCE rate) Xn Dialing mode/CONNECT result codes X0=Blind Dial (ignore Dialtone & Busy), send CONNECT X1=Blind Dial, send CONNECT XXXX X2=follow Dialtone, but ignore Busy, send CONNECT XXXX X3=follow Busy, but ignore Dialtone, send CONNECT XXXX or BUSY X4=send CONNECT XXXX, BUSY, or NO DIALTONE (default) Yn Long Space Disconnect Y0=Not active (default) Y1=Active (see manual) Zn Soft reset and Load Stored profile n (last functional command on line) Z0=resets modem & loads stored profile 0 Z1=resets modem & loads stored profile 1 &Cn DCD signal control &C0=DCD always on &C1=DCD follows carrier state (ON when carrier present) &Dn Modem reaction to DTR on to off transition greater than S25 setting a b c d e (Settings of &Qn) &D0= N 1 3 3 1 &D1= 2 2 3 3 2 &D2= 3 3 3 3 3 &D3= 4 4 3 3 4 List of modem reactions: N=No Action 1=Disconnect & send OK result code 2=Swith to asynchronous command state 3=Disconnect return to command state (Answer disabled while DTR is off) 4=Perform soft reset (like ATZ0) List of &Q states: a. &Q0, &Q5, &Q8, or &Q9 b. &Q1 c. &Q2 d. &Q3 e. &Q4 &Fn Load Factory Default Configuration &F0 No flow control, No error correction, No data compression &F1 MAC hardware flow control, correction & compression active &F2 Hardware flow control, correction & compression active (&F2 is default for DOS, WINDOWS, AMIGA, & STAND ALONE units.) &Jn Phone Jack Selection (&J0 is the only valid setting) &Kn Serial Port Flow Control &K0=None &K3=Bidirectional Hardware (RTS/CTS) &K4=Software (XON/XOFF) &K5=Transparent Software flow control &K6=Software (XON/XOFF) & Hardware (RTS/CTS) flow control &Ln Line Type Selection (&L0 is the only valid setting) &Mn Same function as &Qn setting. &Pn Pulse dialing MAKE/BREAK ratio &P0 39%/61% make/break ratio at 10PPS {US/CANADA} (Default) &P1 33%/67% make/break ratio at 10PPS {UK/Hong Kong} &P2 33%/67% make/break ratio at 20PPS {Japan} &Qn Asynchronous/Synchronous Mode Selection &Q0 Asynchronous Direct mode &Q1 Synchronous Mode 1 (Terminal must support both modes.) Call placed Async, modem switches to Sync. When DTR is dropped modem returns to Async. &Q2 Synchronous Mode 2 Modem dials number in stored location 0 when DTR goes from LOW to HIGH. &Q3 Synchronous Mode 3 Dial number manually on a telephone, and then bring DTR high to let the modems connect. &Q4 Not Used &Q5 Asynchronous Reliable Mode (most common default) &Q6 Asynchronous Normal Mode &Q7 Not used &Q8 Asynchronous Reliable Mode w/o v.42/v.42bis &Q9 Asynchronous Reliable Mode w/o MNP 2-5 &Rn RTS Synchronous Mode &R0 CTS responds to RTS (default) &R1 CTS always on unless &K3 is set &Sn DSR Action Select &S0 Always on (default) &S1 Follows EIA specification &Tn Modem test modes for trained technicians (you must set the serial port at 2400 or 9600, and set the modem with AT&F0) AT&T0 Terminate test in progress AT&T1 Local Analog Loopback AT&T3 Local Digital Loopback for remote modem AT&T4 Grant request for Remote Digital Loopback (default) AT&T5 Prohibit request for Remote Digital Loopback AT&T6 Remote Digital Loopback AT&T7 Remote Digital Loopback with self-test AT&T8 Local Analog Loopback with self-test &V Display Configuration Profiles &Wn Write ACTIVE Profile to Stored Profile n &W0 Writes to profile 0 &W1 Writes to profile 1 &Xn Synchronous Transmit Clock Source &X0=Modem generated (default) &X1=DTE supplied &X2=Derived from the data carrier received from the remote modem. &Yn Select Configuration Loaded at power-up &Y0=Load profile 0 (default) &Y1=Load profile 1 &Zx=n Write stored telephone number x (0 to 3) the number n. \An Maximum MNP Block Size for Stream Links \A0 64 characters \A1 128 characters (default) \A2 192 characters \A3 256 characters \Bn Transmit Break of length n x 100ms where n is 1 to 9 (Send Link Attention in MNP mode) \Gn Modem-to-Modem XON/XOFF (software) flow control (ignored if &Q5) \G0=Disabled (default) \G1=Enabled \Kn Break Processing Control (controls remote modem during MNP mode) \K0,\K2,\K4 Enter command state without sending BREAK to remote \K1 Clear Modem & Terminal Buffers & send BREAK to remote \K2 Don't clear Buffers, but send BREAK to remote \K4 Send BREAK to remote in sequence with any transmitted data (default) \Ln MNP Block Transfer Control \L0 Use Stream Mode for MNP Links (default) \L1 Use Block Mode for MNP Links \N Operating Mode \N0 Normal Mode \N1 Direct Mode \N2 MNP Reliable Mode \N3 AutoReliable Mode \O Originate MNP Reliable Mode Request \Tn Set Inactivity Timer (Modem disconnects if no activity in time n) n=0 Timer disabled (default) n=1 to 42 Modem disconnects after n minutes without activity \U Accept MNP Reliable Request (request must occur within 12 seconds) \Y Switch to MNP Reliable Mode \Z Switch from MNP to Normal Mode %Cn MNP5 Data Compression Enable/Disable %C0 Disabled %C1 Enabled %Dn BTLZ Dictionary Size %D0=512 %D1=1024 %D2=2048 (default) %D3=4096 (if one-way compression %M1 or %M2 is enabled) 2048 (if two-way compression %M3) %En Auto Retrain based on line monitor readings %E0=Disabled (Default) %E1=Enabled %Gn Rate Renegotiation based on line monitor readings %G0=Disabled %G1=Enabled (Default) %L Reports Received Signal Level nnn in -dBm. nnn=9 or stronger reports as 9 nnn=10 to 42 reports as value directly nnn=43 or weaker reports as 43 %Mn BTLZ Compression Mode %M0 Disabled %M1 Transmit compression only %M2 Receive compression only %M3 Two-way compresion (default) %P Clear Local & Remote Modems' BTLZ Dictionaries %Q Report Received signal Quality (nnn range 0 to 127) nnn=1 to 8 current signal quality excellent (higher rate may be used) nnn=9 to 20 current signal good (best carrier rate for line condition) nnn=20 to 30 current signal poor (lower carrier rate should be used) nnn=31 to 127 signal very bad (or gone), try forcing a lower rate NOTE: Modem uses 8 and 20 as rate renegotiation watermarks. %Sn Set Maximum BTLZ string length n (6 to 250) (default is 32) #CID=n Caller ID Mode #CID=0 Disable Caller ID (Default) #CID=1 Enable Formatted Caller ID Mode #CID=2 Enable Raw (ASCII printable HEX number) Mode S0=n Number of Rings to Auto Answer (0 to 255) (0 is disable & default) S1=n Number of Rings before last answer. S2=n Escape Code character (0 to 255) (default is 43 "+") S3=n Carriage Return character (0-127) (default is 13) S4=n Line Feed character (0-127) (default is 10) S5=n Backspace character (0-32) (default is 8) S6=n Time to Wait before Blind Dial (2-255 seconds) (default is 2) (Applies only in X,X1, or X3 dialing mode) S7=n Time to Wait for Carrier (1-255 seconds) (default is 50) S8=n Pause Time for Comma Dial Command (0-255 seconds) (default is 2) S9=n Time to Wait Before Recognizing Carrier (1-255 1/10 seconds) (Default is 6) S10=n Delay from Lost Carrier to Hang Up (1-255 1/10 seconds) (Default is 14) S11=n DTMF Tone Duration/Spacing (35 to 255 1/1000 seconds) (Default is 95) S12=n Escape Code Guard Time (0 to 255 1/50 seconds) (0 to disable, the default is 50) S14 Bit Mapped Option State Codes S16 Diagnostic Test Mode setting -Bit Mapped (default 0) 0 &T1 0 Disable 1 Enable 1 Not Used 2 &T3 0 Disable 1 Enable 3 &T4/&T5 0 Off 1 In progress 4 &T6 0 Disable 1 Enable 5 &T7 0 Disable 1 Enable 6 &T8 0 Disable 1 Enable 7 Not Used S18=n Test Mode Timer (0-255 seconds, 0=Runs endlessly) S21 Bit Mapped Option State Codes S22 Bit Mapped Option State Codes S23 Bit Mapped Option State Codes S25=n Delay to DTR (0-255 1/100 seconds, 5 default) S26=n RTS/CTS Delay (0-255 1/100 seconds, 1 default) (Sync mode only) S27 Bit Mapped Option State Codes S30=n Inactivity Timer (0-255 Unit 10 seconds, 0=disable {default}) In Reliable mode any data transfer resets timer. In Normal mode only sent data resets timer. S36=n Negotiation Failure Treatment (0-7 7 is default) Fallback options when S48=128 or error correction link fails: 0 Disconnect 1 Establish Direct connection 2 Undefined 3 Establish Normal connection 4 Establish a MNP connection if possible, else Disconnect 5 Establish a MNP connection if possible, else Direct connection 6 Undefined 7 Establish a MNP connection if possible, else Normal connection S37=n Forced Single Carrier Rate (0-12 0 is default) 0 Carrier Rate at the rate the last AT command was issued. (If rate is above highest carrier rate, then the highest carrier rate the modem supports is used.) 1 300 bps 2-4 Undefined 5 1200 bps 6 2400 bps 7 Undefined 8 4800 bps 9 9600 bps 10 12000 bps 11 14400 bps 12 7200 bps S38=n Delay Before Forced Disconnect (0-255 seconds, default 20) 0-254 Delay in seconds from H command, or DTR toggle ON or OFF (if modem is set to follow DTR), before modem disconnects. 255 Modem send data out of buffer until completed or connection is lost. S40 Bit Mapped Option State Codes S41 Bit Mapped Option State Codes S46=n Protocol Selection (136 or 138) (Affects v.42/v.42bis mode) 136 Disable Compression 138 Enable Compression (default) S48=n v.42 Negotiation (0,7,128) 0 Disable Negotiation, proceed with LAPM 7 Enable Negotiation (default) 128 Disable Negotiation, fallback per S36 setting S82=n LAPM Break Handling Options (3,7,128) 3 Expedited: Modem sends break immediately & data integrity is maintained before and after break. 7 Destructive: Modem sends break immediately & data being processed by each modem at that time is destroyed. 128 In sequence: Modem sends break in sequence with transmitted data & data integrity is maintained before and after the break S86? Report Connection Failure Cause Code 0 Normal Disconnect (no error) 1-3 Undefined 4 Loss of Carrier 5 v.42 negotiation failed 6-8 Undefined 9 Modems could not find common protocol 10-11 Undefined 12 Normal Disconnect initiated by Remote Modem 13 Remote Modem did not respond after 10 retransmissions of the same message 14 Protocol violation S95=n Extended Result Code Control (default sum is 0) Each bit set high in this register enables the corresponding result code regardless of the W command setting. Bit (Decimal Value) 0 (1) CONNECT XXXX result code gives DCE to DCE rate instead of local DTE to DCE rate. 1 (2) Append /ARQ to verbose CONNECT result code if protocol is NONE 2 (4) Enable CARRIER XXXX result code 3 (8) Enable PROTOCOL XXXX result code 4 (16) Undefined 5 (32) Enable COMPRESSION result code 6 (64) Undefined 7 (128) Undefined S109=n v.32/v.32bis Negotiation Rate Selection (default sum is 62) Each bit set high in this register enables the corresponding rate as a valid rate to be used during rate negotiation. Bit (Decimal Value) 0 (1) Unused 1 (2) 4800 bps 2 (4) 7200 bps 3 (8) 9600 bps 4 (16) 12000 bps 5 (32) 14400 bps 6 (64) Unused 7 (128) Unused S110=n v.32/v.32bis Mode & Rate Negotiation Control 0 Normal v.32 mode (no v.32bis support) 1 Normal v.32bis mode 2 v.32bis mode with automatic rate renegotiation (default) 3 v.32bis mode with automatic rate renegotiation starting with the lowest rate set in S109 and working up one defined rate at a time toward the highest rate set in S109 (based on %Q level at each rate prior to stepping up.) (If the modem steps back down, it will also follow the S109 settings.) SCn=n BUSY Detect Watermark Controls Each register "pair" holds the value for each setting. To set a value, divide the setting by 256. The integer goes in the second register, while the remained goes in the first. (A setting of 516 would convert to 2 Remainder 4, and could be set by sending ATSC0=4SC1=2 to the modem.) Settings are in 1/100ths of a second. Default values: Minimum BUSY ON Time SC0=30 SC1=0 Maximum BUSY ON Time SC2=75 SC3=0 Minimum BUSY OFF Time SC4=30 SC5=0 Maximum BUSY OFF Time SC6=75 SC7=0 SC8=n Set number of valid BUSY Pulses before reporting BUSY (4 is default) FAX commands of special interest to Supra Users: +FAE=n (CLASS 1 Only) Adaptive Answer / Silent Answer Mode Control 0 Disable Both 1 Adaptive Answer ONLY 2 Adaptive Answer & Silent Answer 3 Silent Answer ONLY +FAA=n (CLASS 2 Only) Adaptive Answer / Silent Answer Mode Control 0 Disable Both 1 Adaptive Answer ONLY 2 Adaptive Answer & Silent Answer 3 Silent Answer ONLY Connection Result Codes: Nemeric Verbose 0 OK 1 CONNECT (300 bps) 2 RING 3 NO CARRIER 4 ERROR 5 CONNECT 1200 6 NO DIALTONE 7 BUSY 8 NO ANSWER 9 CONNECT 0600 10 CONNECT 2400 11 CONNECT 4800 12 CONNECT 9600 13 CONNECT 7200 14 CONNECT 12000 15 CONNECT 14400 16 CONNECT 19200 17 CONNECT 38400 18 CONNECT 57600 19 CONNECT 115200 (Not Currently Supported on MOST models) 40 CARRIER 300 46 CARRIER 1200 47 CARRIER 2400 49 CARRIER 7200 50 CARRIER 9600 51 CARRIER 12000 52 CARRIER 14400 66 COMPRESSION: CLASS 5 (MNP 5) 67 COMPRESSION: V.42BIS (BTLZ) 69 COMPRESSION: NONE 70 PROTOCOL: NONE 77 PROTOCOL: LAP-M (V.42) 80 PROTOCOL: ALT (MNP) FAX DATA V.32 & V.32BIS EXTERNAL DISPLAY CODES Red LED's OH Off Hook RD Receiving Data SD Sending Data TR Terminal Ready (Follows DTR per &Dn setting) Green LED Display PANEL AA Auto Answer (RI displayed during ring) CD Carrier Detected DC Data Compression in use DI Dialing FX FAX MODE LP LAPM Error Correction in use. M2 MNP2 Error Correction in use. M3 MNP3 Error Correction in use. M4 MNP4 Error Correction in use. M5 MNP5 Data Compression in use. OK Modem Powered Up Correctly and Ready for Use. RE Receive Error while using LAPM or MNP mode. RI Ring Indicator RT Retrain in progress TE Transmit Error while using LPAM or MNP mode. TM Test Mode in use. 3 300 bps connection 12 1200 bps connection 24 2400 bps connection 48 4800 bps connection 72 7200 bps connection 96 9600 bps connection 120 12000 bps connection 144 14400 bps connection